{"product_id":"3000-watt-pure-sine-inverter-100a-charger-transfer-switch","title":"AIMS 3000 Watt Pure Sine Inverter 100A Charger with 120\/240V 30A \u0026 50A Transfer PICOGLF3K12050BY","description":"\u003ch3\u003eShipping will be calculated at checkout - We do not make any money on Shipping if you are charged more for shipping then we are charged you will be refunded the difference - Guaranteed!!\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003eFor a limited time take 10% off this item using coupon code 1P% + coupon code email25 for $25.00 = big savings!!\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe ETL listed to UL 458 standards AIMS 3000 watt pure sine inverter charger has surpassed the ETL requirements and includes a 2 year warranty. This inverter is a a combination of an inverter, battery charger and AC auto-transfer switch into one complete system with a peak DC and AC conversion efficiency of 92%. It is unique as the inverter will bypass 50 amps 120V or 240V and outputs 120, ideal for RVs, work trucks, food trucks and boats. It is packed with unique features and it is one of the most advanced inverter chargers on the market today. This inverter also features power factor corrected, sophisticated multi-stage charging and pure sine wave output with unprecedentedly high surge capability to meet demanding power needs of inductive loads without endangering the equipment.\u003c\/p\u003e\n\u003cp\u003eThe powerful battery charger  is capable of 12 volts at 100 amps, and with power factor corrected, it uses 20-30% less energy from AC input than a standard charger, avoiding nuisance breaker trips or generator overloads. In response to the increasing demand of more advance battery charging, this model is equipped with Battery Temperature Sensing for increased charging precision. The overloads capacity is 300% of continuous output for up to 20 seconds to reliably support tools and equipment longer.\u003c\/p\u003e\n\u003cp\u003eThe transformers have been consistently improved for years to achieve the best balance of conversion efficiency, idle consumption and minimum THD. The idle consumption of the line is ultra-low, roughly 1.5% of its rated power. The AC battery priority switch and auto generator start functionally making it ideal to work in either backup power or renewable energy applications.\u003c\/p\u003e\n\u003cp\u003eIn AC priority mode, when utility AC power cuts off, the transfer relay is de-energized and the load is automatically transferred to the inverter output. Once the qualified AC utility is restored, the relay is energized and the load is automatically transferred to AC utility.\u003c\/p\u003e\n\u003cp\u003eWhen customized to battery priority mode via the DIP switch, the inverter will extract power from external power sources in renewable energy systems and a minimal cycle of the battery will be required. With the availability of the auto generator start, an electrical generator can be integrated into the system as a backup and started when the battery voltage goes low.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFEATURES \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eListed to UL 458 Standards\u003c\/li\u003e\n\u003cli\u003eBypasses 50 amps 120V or 240V and outputs 120V\u003c\/li\u003e\n\u003cli\u003e2 year warranty\u003c\/li\u003e\n\u003cli\u003e3000 watt low frequency inverter\u003c\/li\u003e\n\u003cli\u003e9000 watt surge for 20 seconds -3x surge capability\u003c\/li\u003e\n\u003cli\u003eBattery priority selector\u003c\/li\u003e\n\u003cli\u003eAC direct connect terminal block\u003c\/li\u003e\n\u003cli\u003eGFCI – 20 amps\u003c\/li\u003e\n\u003cli\u003eMarine coated and protected\u003c\/li\u003e\n\u003cli\u003eMulti stage smart charger 100 amps\u003c\/li\u003e\n\u003cli\u003eRemote panel available\u003c\/li\u003e\n\u003cli\u003eAuto gen start\u003c\/li\u003e\n\u003cli\u003eAuto frequency\u003c\/li\u003e\n\u003cli\u003e10msec typical transfer time\u003c\/li\u003e\n\u003cli\u003e7 battery type settings for charger including\u003cspan\u003e including lithium\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003ciframe title=\"vimeo-player\" src=\"https:\/\/player.vimeo.com\/video\/845563944?h=dc6d126b18\" width=\"640\" height=\"360\"\u003e\u003c\/iframe\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSPECIFICATION \u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable width=\"800\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"296\"\u003eContinuous Output Power\u003c\/td\u003e\n\u003ctd width=\"440\"\u003e3000 Watts \/ 3KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Rating (20 secs)\u003c\/td\u003e\n\u003ctd\u003e9000 Watts \/ 9KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting Electric Motor (HP)\u003c\/td\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003ePure Sine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Efficiency\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;92% (Peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Mode Efficiency\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e.9 – 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage (rms)\u003c\/td\u003e\n\u003ctd\u003e120Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Regulation\u003c\/td\u003e\n\u003ctd\u003e± 10% RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±0.3Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Protection\u003c\/td\u003e\n\u003ctd width=\"440\"\u003eYES. Current Limit Function (fault after 1 sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Transfer Time\u003c\/td\u003e\n\u003ctd\u003e10ms (MAX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax THD @ Full Linear Load\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\"\u003eDC INPUT\u003c\/td\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e12 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Start Voltage\u003c\/td\u003e\n\u003ctd\u003e10Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Battery Alarm\u003c\/td\u003e\n\u003ctd\u003e10.5Vdc \/ 11.Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Battery Trip\u003c\/td\u003e\n\u003ctd\u003e10Vdc \/ 10.5Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Voltage Alarm \u0026amp; Fault\u003c\/td\u003e\n\u003ctd\u003e16Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh DC Input Recovery\u003c\/td\u003e\n\u003ctd\u003e15.5Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Battery Voltage Recover\u003c\/td\u003e\n\u003ctd\u003e13Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleep Mode Threshold\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;50 Watts (Power Saven On)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"16\"\u003eCHARGE\u003c\/td\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd width=\"440\"\u003eNarrow: 100-135Vac Wide: 90-135Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency Range\u003c\/td\u003e\n\u003ctd width=\"440\"\u003eNarrow: 47-55 ±0.3Hz @ 50Hz, 57-65 ±0.3Hz @ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003eDepends on battery type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharger Breaker Rating (120 Vac)\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Charge Rate\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Charge Protection Shutdown\u003c\/td\u003e\n\u003ctd\u003e15.7V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eFast Vdc        Float Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGel USA\u003c\/td\u003e\n\u003ctd\u003e14           13.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAGM 1\u003c\/td\u003e\n\u003ctd\u003e14.1        13.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAGM 2\u003c\/td\u003e\n\u003ctd\u003e14.6        13.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealed Lead Acid\u003c\/td\u003e\n\u003ctd\u003e14.4        13.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGel Euro\u003c\/td\u003e\n\u003ctd\u003e14.4        13.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen Lead Acid\u003c\/td\u003e\n\u003ctd\u003e14.8        13.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLithium\u003c\/td\u003e\n\u003ctd width=\"440\"\u003e14.4 (NOTE: INVERTER MAY SAY CALCIUM BUT CHARGING ALGORITHM BUILT INTO THE INVERTER IS FOR LITHIUM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDe-sulphation\u003c\/td\u003e\n\u003ctd\u003e15.5 for 4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Temp Sensor\u003c\/td\u003e\n\u003ctd\u003eYES. Part # PICGLFBATS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"16\"\u003eBYPASS \u0026amp; PROTECTION\u003c\/td\u003e\n\u003ctd\u003eInput Voltage Waveform\u003c\/td\u003e\n\u003ctd\u003ePure sine from grid or generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Votage\u003c\/td\u003e\n\u003ctd\u003e120Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Voltage Trip\u003c\/td\u003e\n\u003ctd\u003e80V\/100V ±4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Voltage Re-engage\u003c\/td\u003e\n\u003ctd\u003e90V\/100V ±4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Voltage Trip\u003c\/td\u003e\n\u003ctd\u003e140V ±4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Voltage Re-engage\u003c\/td\u003e\n\u003ctd\u003e135V ±4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Input AC Voltage\u003c\/td\u003e\n\u003ctd\u003e150Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz or 60Hz (auto detect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Freq Trip\u003c\/td\u003e\n\u003ctd width=\"440\"\u003eNarrow: 47 ±0.3Hz @ 50Hz, 57 ±0.3Hz @ 60Hz                                 Wide: 40 ±0.3Hz for 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Freq Re-engage\u003c\/td\u003e\n\u003ctd width=\"440\"\u003eNarrow: 48 ±0.3Hz @ 50Hz, 58 ±0.3Hz @ 60Hz                                  Wide: 45 ±0.3Hz for 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Freq Trip\u003c\/td\u003e\n\u003ctd width=\"440\"\u003eNarrow: 55 ±0.3Hz @ 50Hz, 65 ±0.3Hz @ 60Hz                                  Wide: No limit for 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Freq Re-engage\u003c\/td\u003e\n\u003ctd width=\"440\"\u003eNarrow: 54 ±0.3Hz @ 50Hz, 64 ±0.3Hz @ 60Hz                                 Wide: No limit for 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Short Cirucit Protection\u003c\/td\u003e\n\u003ctd\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBypass Breaker Rating (120 Vac)\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBypass Breaker Rating (240 Vac)\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGFCI Rating\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"7\"\u003eMECHANICAL\u003c\/td\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePredrilled holes for wall\/ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e16.25″L x 11″W x 7″H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e59 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e21″H x 14″W x 12″H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e64 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplays\u003c\/td\u003e\n\u003ctd\u003eStatus LEDs\/Optional LCD Remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"AIMS","offers":[{"title":"Default Title","offer_id":51159304929601,"sku":"PICOGLF3K12050BY","price":1406.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0272\/2601\/3761\/files\/PICOGLF10W12V120VBACK06-600x600.jpg?v=1766533624","url":"https:\/\/backupgeneratorstore.com\/products\/3000-watt-pure-sine-inverter-100a-charger-transfer-switch","provider":"Backup Generator Store","version":"1.0","type":"link"}